MSX CT 500 – 3D X-Ray Computed TomographyDownload Information Doc: MSX_CT500.pdf
Key Features: • Worldwide fastest 3D reconstruction algorithm(FraunhoferEZRT) • Reconstruction online to measurement possible(up to 4k x 4k; 16bit) • Motorized movement of sample • Real 3D CT system, not only an upgrade of a 2D system • Horizontal orientation of the path of rays allowsthe inspection of flexible samples • Best cost to performance relationship • Granite base with high accuracy axis system • Integrated sample holder rack • Region of Interest (ROI) measurements possible • Motorized Door • Light-grid for collision protection in front of detector
Options: • Measurement area enhancement • Ring artefactsuppression • PC cluster upgrade • Swing Laminography for flat samples • 3D visualisation software • Several analysis software packages
Standard Configurations: •160kV or 225kV open tube with TXI –True X-Ray Intensity, flat panel detector • 2 Webcams inside the system for process control • Customized solutions possible 
|